Power System Protection
Relays, coordination and protection of lines, transformers, buses, generators and motors: fault studies, instrument transformers, overcurrent, directional, distance, pilot and differential schemes, breaker failure, distributed resources and arc flash, worked through a full substation protection study.
ELE-480 Year 4 3 credits 12 lessons · 4 h 20 min ▶ Video lessons coming soon
Offered by HSM University · Electrical Engineering
This is the American version of this course. See the Canadian version.
What you'll learn
- Explain the purpose of power system protection, the qualities of dependability, security, selectivity and speed, and how overlapping zones, primary protection and backup protection are arranged.
- Calculate three-phase, line-to-line, line-to-ground and double-line-to-ground fault currents with symmetrical components, including fault resistance and the effect of delta-wye transformers, under maximum and minimum conditions.
- Specify and check current and voltage transformers for protection, including accuracy classes, burden, saturation from DC offset, CVT transients and loss of potential.
- Apply instantaneous and inverse-time overcurrent elements using the IEEE and IEC curve equations, and choose pickups, curves and time dials for phase and ground elements.
- Coordinate feeder relays, reclosers, sectionalizers and fuses on a distribution feeder, including fuse saving and fuse blowing, and evaluate the limits of each.
- Explain directional elements and their polarizing quantities, set a zero-sequence directional element, and assess ground fault sensitivity in the presence of fault resistance.
- Set stepped distance zones for a transmission line in primary and secondary ohms, including zero-sequence compensation, infeed effects and relay loadability checks.
- Compare POTT, DCB and line current differential schemes, their channels and their behavior when the channel fails, and calculate their clearing times.
- Set transformer differential protection with ratio compensation, percentage restraint and harmonic restraint, and specify sudden pressure, overexcitation and backup protection.
- Select and set generator protection functions, including loss of field, reverse power and negative-sequence protection, and protect induction motors against stalling and overload.
- Design high-impedance bus differential protection and breaker failure schemes, and apply automatic reclosing with appropriate dead times, synchronism checks and blocking.
- Assess the protection impacts of distributed energy resources under IEEE 1547-2018, calculate arc flash incident energy for NFPA 70E compliance, apply cybersecurity principles to protection systems, and assemble a substation protection study.
Course content
12 lessons · 4 h 20 min total · final exam
- 1 Protection principles and zones of protection 24 min · quiz
- 2 Fault analysis for protection 22 min · quiz
- 3 Instrument transformers 21 min · quiz
- 4 Overcurrent relays and time-current curves 21 min · quiz
- 5 Distribution feeder coordination 22 min · quiz
- 6 Directional and ground fault protection 21 min · quiz
- 7 Distance protection of transmission lines 21 min · quiz
- 8 Pilot schemes and communications 21 min · quiz
- 9 Transformer protection 22 min · quiz
- 10 Generator and motor protection 21 min · quiz
- 11 Bus protection, breaker failure and reclosing 21 min · quiz
- 12 Distributed resources, arc flash and the substation protection study 23 min · quiz
- E Final exam 20 questions
Requirements
Recommended background. You can start any course at any time.
Description
Relays, coordination and protection of lines, transformers, buses, generators and motors: fault studies, instrument transformers, overcurrent, directional, distance, pilot and differential schemes, breaker failure, distributed resources and arc flash, worked through a full substation protection study.
Part of the Engineering stream, typically taken in year 4.