Air Conditioning and Heat Pumps
Residential and light commercial air conditioning and heat pumps, followed through a third-year apprentice in Louisville: system types and SEER2, EER2 and HSPF2 ratings under DOE's regional standards; reversing valves, COP and balance points; defrost and supplementary heat; ductless and multi-zone systems; inverter and communicating equipment; cold-climate heat pumps and dual-fuel changeover; sizing with Manual J and Manual S; installation, line sets, electrical and condensate; rooftop units and economizers; commissioning A2L equipment; maintenance and capacity testing; and troubleshooting, ending with a propane-to-heat-pump retrofit.
RAC-320 12 lessons · 3 h 37 min ▶ Video lessons coming soon
Offered by HSM University · HVAC-R
This is the American version of this course. See the Canadian version.
What you'll learn
- Describe split, packaged, rooftop and ductless air conditioning and heat pump systems, and interpret SEER2, EER2, HSPF2, COP and AHRI ratings and the minimum efficiency rules that apply in the United States
- Explain how a heat pump reverses its cycle, why its capacity and COP fall in cold weather, and find a house's thermal balance point from capacity data and heat loss
- Explain why outdoor coils frost and what happens in a reverse-cycle defrost, and size, stage and control supplementary and emergency heat
- Select, place and install ductless and multi-zone systems, including head selection, combination ratios, flare joints, interconnects and condensate
- Explain how inverter-driven and communicating systems modulate capacity, why they are efficient at part load, and how to charge, test and diagnose them safely
- Evaluate cold-climate heat pumps from extended capacity data and specifications, and set dual-fuel changeover from the thermal and economic balance points
- Use calculated loads from Manual J and Manual S and design temperatures to select equipment, and explain the effects of oversizing and undersizing
- Install split systems and heat pumps with correct outdoor placement, line set sizing and insulation, charge adjustment for line length, electrical circuits and condensate drainage
- Describe rooftop units, economizers and ventilation, estimate capacity from airflow and temperature, and plan a rooftop unit replacement safely
- Commission split systems and A2L heat pumps, verifying airflow, charge, both modes, defrost, refrigerant detection and control settings, and hand the system over to the owner
- Carry out preventive maintenance, use quick performance indicators and measure delivered capacity by the enthalpy method against extended data
- Troubleshoot heat pumps methodically, including reversing valve, defrost, airflow and backup heat faults, and evaluate the results of a heat pump retrofit
Course content
12 lessons · 3 h 37 min total · final exam
- 1 Air conditioning and heat pump systems: types and efficiency ratings 18 min · quiz
- 2 Heat pump fundamentals: reversing valves, COP and balance points 19 min · quiz
- 3 Heat pump defrost and supplementary heat 19 min · quiz
- 4 Ductless mini-splits and multi-zone systems 18 min · quiz
- 5 Inverter-driven and communicating systems 19 min · quiz
- 6 Cold-climate heat pumps and dual-fuel systems 17 min · quiz
- 7 Equipment selection and sizing 18 min · quiz
- 8 Installation: placement, line sets, electrical and condensate 18 min · quiz
- 9 Packaged and rooftop units for light commercial buildings 17 min · quiz
- 10 Start-up and commissioning, including A2L equipment 18 min · quiz
- 11 Maintenance and performance testing 18 min · quiz
- 12 Troubleshooting heat pumps and the Novak retrofit capstone 18 min · quiz
- E Final exam 20 questions
Requirements
Recommended background. You can start any course at any time.
Description
Residential and light commercial air conditioning and heat pumps, followed through a third-year apprentice in Louisville: system types and SEER2, EER2 and HSPF2 ratings under DOE's regional standards; reversing valves, COP and balance points; defrost and supplementary heat; ductless and multi-zone systems; inverter and communicating equipment; cold-climate heat pumps and dual-fuel changeover; sizing with Manual J and Manual S; installation, line sets, electrical and condensate; rooftop units and economizers; commissioning A2L equipment; maintenance and capacity testing; and troubleshooting, ending with a propane-to-heat-pump retrofit.