Air Conditioning and Heat Pumps
Residential and light commercial air conditioning and heat pumps, followed through a third-year apprentice in Kitchener: system types and SEER2, EER2 and HSPF2 ratings under Canada's efficiency regulations; reversing valves, COP and balance points; defrost and supplementary heat; ductless and multi-zone systems; inverter and communicating equipment; cold-climate heat pumps and dual-fuel changeover; sizing with CSA F280; installation, line sets, electrical and condensate; rooftop units and economizers; commissioning A2L equipment; maintenance and capacity testing; and troubleshooting, ending with an oil-to-heat-pump retrofit.
RAC-320 12 lessons · 3 h 39 min ▶ Video lessons coming soon
Offered by HSM University · Refrigeration and Air Conditioning
This is the Canadian version of this course. See the American version.
What you'll learn
- Describe split, packaged, rooftop and ductless air conditioning and heat pump systems, and interpret SEER2, EER2, HSPF2, COP and AHRI ratings and the minimum efficiency rules that apply in Canada
- Explain how a heat pump reverses its cycle, why its capacity and COP fall in cold weather, and find a house's thermal balance point from capacity data and heat loss
- Explain why outdoor coils frost and what happens in a reverse-cycle defrost, and size, stage and control supplementary and emergency heat
- Select, place and install ductless and multi-zone systems, including head selection, combination ratios, flare joints, interconnects and condensate
- Explain how inverter-driven and communicating systems modulate capacity, why they are efficient at part load, and how to charge, test and diagnose them safely
- Evaluate cold-climate heat pumps from extended capacity data and specifications, and set dual-fuel changeover from the thermal and economic balance points
- Use calculated loads from CSA F280 and design temperatures to select equipment, and explain the effects of oversizing and undersizing
- Install split systems and heat pumps with correct outdoor placement, line set sizing and insulation, charge adjustment for line length, electrical circuits and condensate drainage
- Describe rooftop units, economizers and ventilation, estimate capacity from airflow and temperature, and plan a rooftop unit replacement safely
- Commission split systems and A2L heat pumps, verifying airflow, charge, both modes, defrost, refrigerant detection and control settings, and hand the system over to the owner
- Carry out preventive maintenance, use quick performance indicators and measure delivered capacity by the enthalpy method against extended data
- Troubleshoot heat pumps methodically, including reversing valve, defrost, airflow and backup heat faults, and evaluate the results of a heat pump retrofit
Course content
12 lessons · 3 h 39 min total · final exam
- 1 Air conditioning and heat pump systems: types and efficiency ratings 19 min · quiz
- 2 Heat pump fundamentals: reversing valves, COP and balance points 19 min · quiz
- 3 Heat pump defrost and supplementary heat 19 min · quiz
- 4 Ductless mini-splits and multi-zone systems 18 min · quiz
- 5 Inverter-driven and communicating systems 19 min · quiz
- 6 Cold-climate heat pumps and dual-fuel systems 17 min · quiz
- 7 Equipment selection and sizing 18 min · quiz
- 8 Installation: placement, line sets, electrical and condensate 18 min · quiz
- 9 Packaged and rooftop units for light commercial buildings 18 min · quiz
- 10 Start-up and commissioning, including A2L equipment 18 min · quiz
- 11 Maintenance and performance testing 18 min · quiz
- 12 Troubleshooting heat pumps and the Novak retrofit capstone 18 min · quiz
- E Final exam 20 questions
Requirements
Recommended background. You can start any course at any time.
Description
Residential and light commercial air conditioning and heat pumps, followed through a third-year apprentice in Kitchener: system types and SEER2, EER2 and HSPF2 ratings under Canada's efficiency regulations; reversing valves, COP and balance points; defrost and supplementary heat; ductless and multi-zone systems; inverter and communicating equipment; cold-climate heat pumps and dual-fuel changeover; sizing with CSA F280; installation, line sets, electrical and condensate; rooftop units and economizers; commissioning A2L equipment; maintenance and capacity testing; and troubleshooting, ending with an oil-to-heat-pump retrofit.