Air Conditioning and Heat Pumps

Residential and light commercial air conditioning and heat pumps, followed through a third-year apprentice in Kitchener: system types and SEER2, EER2 and HSPF2 ratings under Canada's efficiency regulations; reversing valves, COP and balance points; defrost and supplementary heat; ductless and multi-zone systems; inverter and communicating equipment; cold-climate heat pumps and dual-fuel changeover; sizing with CSA F280; installation, line sets, electrical and condensate; rooftop units and economizers; commissioning A2L equipment; maintenance and capacity testing; and troubleshooting, ending with an oil-to-heat-pump retrofit.

RAC-320 12 lessons · 3 h 39 min ▶ Video lessons coming soon

Offered by HSM University · Refrigeration and Air Conditioning

This is the Canadian version of this course. See the American version.

What you'll learn

  • Describe split, packaged, rooftop and ductless air conditioning and heat pump systems, and interpret SEER2, EER2, HSPF2, COP and AHRI ratings and the minimum efficiency rules that apply in Canada
  • Explain how a heat pump reverses its cycle, why its capacity and COP fall in cold weather, and find a house's thermal balance point from capacity data and heat loss
  • Explain why outdoor coils frost and what happens in a reverse-cycle defrost, and size, stage and control supplementary and emergency heat
  • Select, place and install ductless and multi-zone systems, including head selection, combination ratios, flare joints, interconnects and condensate
  • Explain how inverter-driven and communicating systems modulate capacity, why they are efficient at part load, and how to charge, test and diagnose them safely
  • Evaluate cold-climate heat pumps from extended capacity data and specifications, and set dual-fuel changeover from the thermal and economic balance points
  • Use calculated loads from CSA F280 and design temperatures to select equipment, and explain the effects of oversizing and undersizing
  • Install split systems and heat pumps with correct outdoor placement, line set sizing and insulation, charge adjustment for line length, electrical circuits and condensate drainage
  • Describe rooftop units, economizers and ventilation, estimate capacity from airflow and temperature, and plan a rooftop unit replacement safely
  • Commission split systems and A2L heat pumps, verifying airflow, charge, both modes, defrost, refrigerant detection and control settings, and hand the system over to the owner
  • Carry out preventive maintenance, use quick performance indicators and measure delivered capacity by the enthalpy method against extended data
  • Troubleshoot heat pumps methodically, including reversing valve, defrost, airflow and backup heat faults, and evaluate the results of a heat pump retrofit

Course content

12 lessons · 3 h 39 min total · final exam

  1. 1 Air conditioning and heat pump systems: types and efficiency ratings 19 min · quiz
  2. 2 Heat pump fundamentals: reversing valves, COP and balance points 19 min · quiz
  3. 3 Heat pump defrost and supplementary heat 19 min · quiz
  4. 4 Ductless mini-splits and multi-zone systems 18 min · quiz
  5. 5 Inverter-driven and communicating systems 19 min · quiz
  6. 6 Cold-climate heat pumps and dual-fuel systems 17 min · quiz
  7. 7 Equipment selection and sizing 18 min · quiz
  8. 8 Installation: placement, line sets, electrical and condensate 18 min · quiz
  9. 9 Packaged and rooftop units for light commercial buildings 18 min · quiz
  10. 10 Start-up and commissioning, including A2L equipment 18 min · quiz
  11. 11 Maintenance and performance testing 18 min · quiz
  12. 12 Troubleshooting heat pumps and the Novak retrofit capstone 18 min · quiz
  13. E Final exam 20 questions

Requirements

Recommended background. You can start any course at any time.

Description

Residential and light commercial air conditioning and heat pumps, followed through a third-year apprentice in Kitchener: system types and SEER2, EER2 and HSPF2 ratings under Canada's efficiency regulations; reversing valves, COP and balance points; defrost and supplementary heat; ductless and multi-zone systems; inverter and communicating equipment; cold-climate heat pumps and dual-fuel changeover; sizing with CSA F280; installation, line sets, electrical and condensate; rooftop units and economizers; commissioning A2L equipment; maintenance and capacity testing; and troubleshooting, ending with an oil-to-heat-pump retrofit.