Metering Devices and System Charging

Metering devices and refrigerant charging, followed through a second-year apprentice at an HVAC-R contractor in Kitchener: what every metering device does; capillary tubes and fixed orifices; thermostatic expansion valves, their bulbs, equalizers, setup and troubleshooting; electronic expansion valves and their sensors; automatic expansion valves and float metering; superheat and subcooling diagnostics; evacuation and decay testing; charging by weight, superheat, subcooling and manufacturer charts; blends with glide, low ambient and inverter systems; and safe charging of A2L refrigerants under CSA B52.

RAC-220 12 lessons · 3 h 25 min ▶ Video lessons coming soon

Offered by HSM University · Refrigeration and Air Conditioning

This is the Canadian version of this course. See the American version.

What you'll learn

  • Explain the two jobs of every metering device, calculate how subcooling reduces flash gas, and recognize starved, flooded and correctly fed evaporators
  • Describe how capillary tubes and fixed orifices meter, match pistons and capillary tubes to the system, and diagnose restrictions in critical-charge systems
  • Explain the force balance, bulb charges, equalizers and port designs of thermostatic expansion valves and distinguish static, opening and operating superheat
  • Install TXVs and mount their bulbs correctly, measure operating superheat at the bulb, and diagnose hunting, overfeeding and starving before adjusting a valve
  • Describe stepper and pulse-width-modulated electronic expansion valves and their controllers, and check coils, sensors and live data to separate valve, board and charge faults
  • Explain how automatic expansion valves and float valves meter refrigerant and judge flooded evaporators by level and approach temperature
  • Take a complete set of readings at stable conditions and use superheat, subcooling, pressures and temperature splits to identify common charge and component faults
  • Evacuate systems with correct tools and procedures, interpret decay tests to distinguish leaks from moisture, and maintain vacuum pumps
  • Charge systems by weight with line set adjustment and verify them by target superheat, target subcooling or the manufacturer's charts
  • Charge zeotropic blends correctly using dew and bubble points, apply low ambient charging limits and head pressure control charge, and follow manufacturers' methods for inverter systems
  • Apply A2L safety classes, codes and charge limits, use A2L-rated tools and cylinders, and charge, label and commission A2L systems with refrigerant detection
  • Apply a systematic method to charge-related complaints, repair causes before charging, and keep complete records of readings, repairs and refrigerant amounts

Course content

12 lessons · 3 h 25 min total · final exam

  1. 1 The metering device's job 18 min · quiz
  2. 2 Capillary tubes and fixed orifices 17 min · quiz
  3. 3 Thermostatic expansion valves 18 min · quiz
  4. 4 TXV setup, bulb placement and troubleshooting 17 min · quiz
  5. 5 Electronic expansion valves 17 min · quiz
  6. 6 Automatic expansion valves and float metering 17 min · quiz
  7. 7 Superheat and subcooling diagnostics 17 min · quiz
  8. 8 Evacuation and dehydration 17 min · quiz
  9. 9 Charging methods: weight, superheat and subcooling 17 min · quiz
  10. 10 Charging refrigerant blends, low ambient and inverter systems 16 min · quiz
  11. 11 A2L refrigerants: safe charging and service 17 min · quiz
  12. 12 Charge troubleshooting, documentation and the capstone 17 min · quiz
  13. E Final exam 20 questions

Requirements

Recommended background. You can start any course at any time.

Description

Metering devices and refrigerant charging, followed through a second-year apprentice at an HVAC-R contractor in Kitchener: what every metering device does; capillary tubes and fixed orifices; thermostatic expansion valves, their bulbs, equalizers, setup and troubleshooting; electronic expansion valves and their sensors; automatic expansion valves and float metering; superheat and subcooling diagnostics; evacuation and decay testing; charging by weight, superheat, subcooling and manufacturer charts; blends with glide, low ambient and inverter systems; and safe charging of A2L refrigerants under CSA B52.