Initiating and Notification Devices

Every device that detects a fire or warns people about one, followed through Bramwell Fire Protection's Saskatoon crew: conventional and addressable reporting, photoelectric, ionization, multi-criteria, duct, beam and air-sampling smoke detection, carbon monoxide and video detection, heat and flame detectors, manual stations, sprinkler waterflow and supervisory devices, horns, speakers and strobes, and the CAN/ULC-S524 spacing and placement rules, ending with a device layout for a school wing.

FAT-120 12 lessons · 3 h 49 min ▶ Video lessons coming soon

Offered by HSM University · Fire Alarm Systems

This is the Canadian version of this course. See the American version.

What you'll learn

  • Explain how conventional and addressable initiating devices report alarm, supervisory and trouble conditions, and the role of product listings and installation standards
  • Compare photoelectric and ionization smoke detection, recognize nuisance alarm sources and explain sensitivity, drift and drift compensation
  • Select and install duct, projected beam and air-sampling smoke detection for the spaces each one suits
  • Explain how multi-criteria, carbon monoxide, video and thermal image detection work and how their signals are handled
  • Choose fixed-temperature, rate-of-rise, rate-compensated and linear heat detectors for a space, with ratings that suit its normal temperatures
  • Apply flame detector coverage and false alarm rules, and describe cross-zoned releasing sequences for special hazards
  • Locate and mount manual stations to CAN/ULC-S524 and reduce false pulls without compromising the stations
  • Explain how waterflow, valve tamper and other sprinkler supervisory devices work, are wired and are tested with the sprinkler trade
  • Calculate required audible levels under the National Building Code and place horns and speakers for even coverage
  • Size, mount and synchronize strobes for rooms, corridors and sleeping areas, and account for their current draw
  • Apply spacing rules for smooth, high, sloped, beamed and ventilated ceilings to spot detectors
  • Prepare a device layout and schedule for a building wing and check it against the code, the brief and the other trades' drawings

Course content

12 lessons · 3 h 49 min total · final exam

  1. 1 Initiating devices and how they report 19 min · quiz
  2. 2 Photoelectric and ionization smoke detectors 19 min · quiz
  3. 3 Duct, beam and aspirating smoke detection 19 min · quiz
  4. 4 Multi-criteria, CO and video-based detection 19 min · quiz
  5. 5 Heat detectors: fixed temperature and rate of rise 19 min · quiz
  6. 6 Flame and special hazard detectors 19 min · quiz
  7. 7 Manual pull stations 19 min · quiz
  8. 8 Sprinkler supervisory and waterflow devices 19 min · quiz
  9. 9 Audible notification: horns, speakers and audibility 19 min · quiz
  10. 10 Visual notification: strobes and candela 19 min · quiz
  11. 11 Device spacing and placement rules 19 min · quiz
  12. 12 Capstone: laying out devices for a school wing 20 min · quiz
  13. E Final exam 20 questions

Requirements

Recommended background. You can start any course at any time.

Description

Every device that detects a fire or warns people about one, followed through Bramwell Fire Protection's Saskatoon crew: conventional and addressable reporting, photoelectric, ionization, multi-criteria, duct, beam and air-sampling smoke detection, carbon monoxide and video detection, heat and flame detectors, manual stations, sprinkler waterflow and supervisory devices, horns, speakers and strobes, and the CAN/ULC-S524 spacing and placement rules, ending with a device layout for a school wing.