Codes, Bonding and Grounding for Communications (CEC)
The code side of low-voltage work, followed through Cobalt Line Systems' Ottawa closeout crew on a riser retrofit, a school, a hospital wing and a condo tower: how the Canadian Electrical Code (Ontario Electrical Safety Code), the building code and the TIA standards apply, CEC Sections 16, 56 and 60, cable FT ratings and substitution, plenum, riser and general spaces, separation from power, entrance protectors and outside plant, optical fibre rules, fire separations and tested firestop systems, bonding and grounding, the TIA-607 bonding backbone, and a full code and bonding inspection.
LVT-330 12 lessons · 3 h 49 min ▶ Video lessons coming soon
Offered by HSM University · Low Voltage Systems
This is the Canadian version of this course. See the American version.
What you'll learn
- Explain how the electrical code, the building code, product standards, cabling standards and specifications govern low-voltage work in Ontario, and who enforces them
- Identify which parts of CEC Sections 16, 56 and 60 apply to communication, Class 2 and optical fibre installations
- Read cable legends and apply the fire rating hierarchy and substitution rules to choose and check cables
- Classify plenum, riser and general spaces and determine the minimum cable rating for every segment of a run
- Apply separation, barrier and support rules between low-voltage and power wiring and within shared pathways
- Install and check entrance protectors, bonding conductors, outdoor cable lengths and outside plant pathways
- Apply the rules for nonconductive, conductive and composite optical cables, innerduct and abandoned fibre
- Recognize rated walls and floors and state the firestop ratings each penetration requires
- Select, install, label and record tested firestop systems within their fill and annular space limits
- Explain grounding and bonding, why all systems bond to one grounding system, and why bonding conductors are kept short
- Lay out and size a TIA-607 bonding system with PBB, TBC, TBB, SBB and BBC, and test it
- Plan and carry out a code and bonding inspection, correct deficiencies and hand over complete records
Course content
12 lessons · 3 h 49 min total · final exam
- 1 How electrical codes apply to low-voltage work 20 min · quiz
- 2 CEC Section 16 and Section 60 19 min · quiz
- 3 Cable ratings, listings and markings 19 min · quiz
- 4 Plenum, riser and general-purpose spaces 19 min · quiz
- 5 Separation from power and other systems 19 min · quiz
- 6 Entrances, protectors and outside plant 19 min · quiz
- 7 Optical fibre cable rules 19 min · quiz
- 8 Fire resistance ratings and penetrations 19 min · quiz
- 9 Firestopping systems and installation 19 min · quiz
- 10 Bonding and grounding fundamentals 19 min · quiz
- 11 The telecommunications bonding backbone (TIA-607) 19 min · quiz
- 12 Capstone: a code and bonding inspection of a building 19 min · quiz
- E Final exam 20 questions
Requirements
Recommended background. You can start any course at any time.
Description
The code side of low-voltage work, followed through Cobalt Line Systems' Ottawa closeout crew on a riser retrofit, a school, a hospital wing and a condo tower: how the Canadian Electrical Code (Ontario Electrical Safety Code), the building code and the TIA standards apply, CEC Sections 16, 56 and 60, cable FT ratings and substitution, plenum, riser and general spaces, separation from power, entrance protectors and outside plant, optical fibre rules, fire separations and tested firestop systems, bonding and grounding, the TIA-607 bonding backbone, and a full code and bonding inspection.