Backflow Prevention and Cross-Connection Control
Backflow prevention and cross-connection control under the Ontario Building Code, CSA B64.10 and municipal water by-laws, followed through an apprentice protecting a Hamilton mixed-use tower: why cross-connections matter; backpressure and backsiphonage; surveying buildings for cross-connections; minor, moderate and severe hazards; air gaps and atmospheric vacuum breakers; pressure and spill-resistant vacuum breakers; double check valve assemblies; reduced pressure principle assemblies; premise, zone and fixture isolation; installation requirements; field testing with a differential gauge; and cross-connection control programs, tester certification and records.
PLB-320 12 lessons · 4 h 9 min ▶ Video lessons coming soon
Offered by HSM University · Plumbing
This is the Canadian version of this course. See the American version.
What you'll learn
- Explain why cross-connections endanger public health, using documented waterborne disease and contamination incidents, and describe the shared responsibility of plumbers, owners and water suppliers.
- Distinguish backsiphonage from backpressure, calculate the pressures involved, and identify the building conditions that create each.
- Survey a building for cross-connections, recognize common direct and indirect connections, and record findings in a form a utility can use.
- Classify cross-connections as minor, moderate or severe hazards following the Ontario Building Code and CSA B64.10, and explain how the class sets the level of protection.
- Size air gaps and install atmospheric and hose connection vacuum breakers correctly, including height, downstream valve and continuous pressure limits.
- Describe how pressure and spill-resistant vacuum breakers work, where they may be used, and how high they must be installed above the downstream piping.
- Explain the operation and limits of double check valve assemblies, double check detector assemblies and dual check valves, and account for their pressure loss and thermal expansion effects.
- Explain how a reduced pressure principle assembly protects against both backsiphonage and backpressure, and size the drain for its relief valve discharge.
- Select the correct device for premise, zone and fixture isolation from the hazard, the type of backflow and whether the condition is continuous pressure.
- Install backflow preventers with correct height, clearance, drainage, orientation, strainers and thermal expansion control, and commission them before use.
- Describe field test procedures for reduced pressure assemblies, double checks and vacuum breakers, interpret differential gauge readings, and decide whether a device passes.
- Explain how a cross-connection control program works, including surveys, tester certification, test reports, scheduling and enforcement.
Course content
12 lessons · 4 h 9 min total · final exam
- 1 Why cross-connections matter 20 min · quiz
- 2 The hydraulics of backflow: backpressure and backsiphonage 24 min · quiz
- 3 Cross-connections in buildings 21 min · quiz
- 4 Degrees of hazard: minor, moderate and severe 20 min · quiz
- 5 Air gaps and atmospheric vacuum breakers 21 min · quiz
- 6 Pressure vacuum breakers and spill-resistant vacuum breakers 22 min · quiz
- 7 Double check valve assemblies 21 min · quiz
- 8 Reduced pressure principle assemblies 20 min · quiz
- 9 Selecting the right device: premise, zone and fixture isolation 20 min · quiz
- 10 Installation requirements for backflow preventers 20 min · quiz
- 11 Field testing backflow prevention assemblies 20 min · quiz
- 12 Cross-connection control programs, tester certification and records 20 min · quiz
- E Final exam 20 questions
Requirements
Recommended background. You can start any course at any time.
Description
Backflow prevention and cross-connection control under the Ontario Building Code, CSA B64.10 and municipal water by-laws, followed through an apprentice protecting a Hamilton mixed-use tower: why cross-connections matter; backpressure and backsiphonage; surveying buildings for cross-connections; minor, moderate and severe hazards; air gaps and atmospheric vacuum breakers; pressure and spill-resistant vacuum breakers; double check valve assemblies; reduced pressure principle assemblies; premise, zone and fixture isolation; installation requirements; field testing with a differential gauge; and cross-connection control programs, tester certification and records.