Backflow Prevention and Cross-Connection Control

Backflow prevention and cross-connection control under the Ontario Building Code, CSA B64.10 and municipal water by-laws, followed through an apprentice protecting a Hamilton mixed-use tower: why cross-connections matter; backpressure and backsiphonage; surveying buildings for cross-connections; minor, moderate and severe hazards; air gaps and atmospheric vacuum breakers; pressure and spill-resistant vacuum breakers; double check valve assemblies; reduced pressure principle assemblies; premise, zone and fixture isolation; installation requirements; field testing with a differential gauge; and cross-connection control programs, tester certification and records.

PLB-320 12 lessons · 4 h 9 min ▶ Video lessons coming soon

Offered by HSM University · Plumbing

This is the Canadian version of this course. See the American version.

What you'll learn

  • Explain why cross-connections endanger public health, using documented waterborne disease and contamination incidents, and describe the shared responsibility of plumbers, owners and water suppliers.
  • Distinguish backsiphonage from backpressure, calculate the pressures involved, and identify the building conditions that create each.
  • Survey a building for cross-connections, recognize common direct and indirect connections, and record findings in a form a utility can use.
  • Classify cross-connections as minor, moderate or severe hazards following the Ontario Building Code and CSA B64.10, and explain how the class sets the level of protection.
  • Size air gaps and install atmospheric and hose connection vacuum breakers correctly, including height, downstream valve and continuous pressure limits.
  • Describe how pressure and spill-resistant vacuum breakers work, where they may be used, and how high they must be installed above the downstream piping.
  • Explain the operation and limits of double check valve assemblies, double check detector assemblies and dual check valves, and account for their pressure loss and thermal expansion effects.
  • Explain how a reduced pressure principle assembly protects against both backsiphonage and backpressure, and size the drain for its relief valve discharge.
  • Select the correct device for premise, zone and fixture isolation from the hazard, the type of backflow and whether the condition is continuous pressure.
  • Install backflow preventers with correct height, clearance, drainage, orientation, strainers and thermal expansion control, and commission them before use.
  • Describe field test procedures for reduced pressure assemblies, double checks and vacuum breakers, interpret differential gauge readings, and decide whether a device passes.
  • Explain how a cross-connection control program works, including surveys, tester certification, test reports, scheduling and enforcement.

Course content

12 lessons · 4 h 9 min total · final exam

  1. 1 Why cross-connections matter 20 min · quiz
  2. 2 The hydraulics of backflow: backpressure and backsiphonage 24 min · quiz
  3. 3 Cross-connections in buildings 21 min · quiz
  4. 4 Degrees of hazard: minor, moderate and severe 20 min · quiz
  5. 5 Air gaps and atmospheric vacuum breakers 21 min · quiz
  6. 6 Pressure vacuum breakers and spill-resistant vacuum breakers 22 min · quiz
  7. 7 Double check valve assemblies 21 min · quiz
  8. 8 Reduced pressure principle assemblies 20 min · quiz
  9. 9 Selecting the right device: premise, zone and fixture isolation 20 min · quiz
  10. 10 Installation requirements for backflow preventers 20 min · quiz
  11. 11 Field testing backflow prevention assemblies 20 min · quiz
  12. 12 Cross-connection control programs, tester certification and records 20 min · quiz
  13. E Final exam 20 questions

Requirements

Recommended background. You can start any course at any time.

Description

Backflow prevention and cross-connection control under the Ontario Building Code, CSA B64.10 and municipal water by-laws, followed through an apprentice protecting a Hamilton mixed-use tower: why cross-connections matter; backpressure and backsiphonage; surveying buildings for cross-connections; minor, moderate and severe hazards; air gaps and atmospheric vacuum breakers; pressure and spill-resistant vacuum breakers; double check valve assemblies; reduced pressure principle assemblies; premise, zone and fixture isolation; installation requirements; field testing with a differential gauge; and cross-connection control programs, tester certification and records.