Controls and Building Automation

Refrigeration and HVAC controls, followed through a second-year apprentice at an HVAC-R contractor in Kitchener: control loops, differentials and PID action; temperature sensors and how to check them; thermostats, pressure controls and pump-down; safety controls and lockouts; defrost control; walk-in and display case controllers; electronic, inverter and communicating equipment; economizers and ventilation control under the NECB and Ontario's energy rules; building automation points, sequences and overrides; BACnet, Modbus, RS-485 wiring and defensive cybersecurity; trending, alarms and commissioning; and a systematic method for control calls.

RAC-230 12 lessons · 3 h 33 min ▶ Video lessons coming soon

Offered by HSM University · Refrigeration and Air Conditioning

This is the Canadian version of this course. See the American version.

What you'll learn

  • Describe the parts of open and closed control loops, set two-position differentials that protect compressors from short cycling, and recognize the effects of proportional, integral and derivative action
  • Explain how bimetal elements, thermostatic bulbs, thermistors, RTDs and thermocouples sense temperature, and check sensors and their wiring against a calibrated reference
  • Set up thermostats, liquid line solenoids, low-pressure controls, crankcase heaters, condenser fan cycling and staging for pump-down and normal operation
  • Explain the purpose, wiring, settings and reset types of high- and low-pressure, oil, freeze, flow and motor safety controls, and troubleshoot a tripped safety without defeating it
  • Set defrost initiation, termination, fail-safe, drip and fan delay settings for walk-ins and display cases, and diagnose defrost faults on refrigeration systems and heat pumps
  • Install, program and test electronic walk-in and display case controllers, including probes, door switches, anti-sweat heaters, alarms and logging
  • Use fault codes, test modes and service data on integrated, inverter and communicating equipment, check pressure transducers and troubleshoot communication faults safely
  • Check minimum ventilation, demand-controlled ventilation and economizer dampers, sensors and changeover settings, and calculate the outdoor air fraction from temperatures
  • Describe the structure of a building automation system, its point types, sequences of operation, schedules and overrides, and use command and status to find faults
  • Explain how BACnet and Modbus devices communicate, install and check RS-485 field buses, and apply basic defensive cybersecurity practices to building systems
  • Collect and read trend data, apply simple fault detection rules, manage alarms so people act on them and take part in commissioning and functional testing
  • Apply a systematic control troubleshooting method that finds the disagreement between what a control believes and what the equipment is doing, and document the repair

Course content

12 lessons · 3 h 33 min total · final exam

  1. 1 Control fundamentals: loops, differentials and PID 21 min · quiz
  2. 2 Temperature sensors and how to check them 19 min · quiz
  3. 3 Operating controls: thermostats, pressure controls and pump-down 17 min · quiz
  4. 4 Safety controls and lockouts 18 min · quiz
  5. 5 Defrost control 17 min · quiz
  6. 6 Walk-in and display case controllers 17 min · quiz
  7. 7 Electronic and communicating HVAC controls 18 min · quiz
  8. 8 Economizers and ventilation control 17 min · quiz
  9. 9 Building automation fundamentals 17 min · quiz
  10. 10 BAS networks, protocols and cybersecurity 18 min · quiz
  11. 11 Trending, alarms and commissioning 17 min · quiz
  12. 12 Control troubleshooting: the capstone calls 17 min · quiz
  13. E Final exam 20 questions

Requirements

Recommended background. You can start any course at any time.

Description

Refrigeration and HVAC controls, followed through a second-year apprentice at an HVAC-R contractor in Kitchener: control loops, differentials and PID action; temperature sensors and how to check them; thermostats, pressure controls and pump-down; safety controls and lockouts; defrost control; walk-in and display case controllers; electronic, inverter and communicating equipment; economizers and ventilation control under the NECB and Ontario's energy rules; building automation points, sequences and overrides; BACnet, Modbus, RS-485 wiring and defensive cybersecurity; trending, alarms and commissioning; and a systematic method for control calls.