Controls and Building Automation
Refrigeration and HVAC controls, followed through a second-year apprentice at an HVAC-R contractor in Kitchener: control loops, differentials and PID action; temperature sensors and how to check them; thermostats, pressure controls and pump-down; safety controls and lockouts; defrost control; walk-in and display case controllers; electronic, inverter and communicating equipment; economizers and ventilation control under the NECB and Ontario's energy rules; building automation points, sequences and overrides; BACnet, Modbus, RS-485 wiring and defensive cybersecurity; trending, alarms and commissioning; and a systematic method for control calls.
RAC-230 12 lessons · 3 h 33 min ▶ Video lessons coming soon
Offered by HSM University · Refrigeration and Air Conditioning
This is the Canadian version of this course. See the American version.
What you'll learn
- Describe the parts of open and closed control loops, set two-position differentials that protect compressors from short cycling, and recognize the effects of proportional, integral and derivative action
- Explain how bimetal elements, thermostatic bulbs, thermistors, RTDs and thermocouples sense temperature, and check sensors and their wiring against a calibrated reference
- Set up thermostats, liquid line solenoids, low-pressure controls, crankcase heaters, condenser fan cycling and staging for pump-down and normal operation
- Explain the purpose, wiring, settings and reset types of high- and low-pressure, oil, freeze, flow and motor safety controls, and troubleshoot a tripped safety without defeating it
- Set defrost initiation, termination, fail-safe, drip and fan delay settings for walk-ins and display cases, and diagnose defrost faults on refrigeration systems and heat pumps
- Install, program and test electronic walk-in and display case controllers, including probes, door switches, anti-sweat heaters, alarms and logging
- Use fault codes, test modes and service data on integrated, inverter and communicating equipment, check pressure transducers and troubleshoot communication faults safely
- Check minimum ventilation, demand-controlled ventilation and economizer dampers, sensors and changeover settings, and calculate the outdoor air fraction from temperatures
- Describe the structure of a building automation system, its point types, sequences of operation, schedules and overrides, and use command and status to find faults
- Explain how BACnet and Modbus devices communicate, install and check RS-485 field buses, and apply basic defensive cybersecurity practices to building systems
- Collect and read trend data, apply simple fault detection rules, manage alarms so people act on them and take part in commissioning and functional testing
- Apply a systematic control troubleshooting method that finds the disagreement between what a control believes and what the equipment is doing, and document the repair
Course content
12 lessons · 3 h 33 min total · final exam
- 1 Control fundamentals: loops, differentials and PID 21 min · quiz
- 2 Temperature sensors and how to check them 19 min · quiz
- 3 Operating controls: thermostats, pressure controls and pump-down 17 min · quiz
- 4 Safety controls and lockouts 18 min · quiz
- 5 Defrost control 17 min · quiz
- 6 Walk-in and display case controllers 17 min · quiz
- 7 Electronic and communicating HVAC controls 18 min · quiz
- 8 Economizers and ventilation control 17 min · quiz
- 9 Building automation fundamentals 17 min · quiz
- 10 BAS networks, protocols and cybersecurity 18 min · quiz
- 11 Trending, alarms and commissioning 17 min · quiz
- 12 Control troubleshooting: the capstone calls 17 min · quiz
- E Final exam 20 questions
Requirements
Recommended background. You can start any course at any time.
Description
Refrigeration and HVAC controls, followed through a second-year apprentice at an HVAC-R contractor in Kitchener: control loops, differentials and PID action; temperature sensors and how to check them; thermostats, pressure controls and pump-down; safety controls and lockouts; defrost control; walk-in and display case controllers; electronic, inverter and communicating equipment; economizers and ventilation control under the NECB and Ontario's energy rules; building automation points, sequences and overrides; BACnet, Modbus, RS-485 wiring and defensive cybersecurity; trending, alarms and commissioning; and a systematic method for control calls.